References For Liquid Chromatography

Alnouti Y. et al., 2005. Development and application of a new online SPE high throughput direct analysis of pharmaceutical compounds in plasma. J Chromatogr A 1080: 99. Alnouti Y. et al., 2006. Method for internal standard introduction for quantitative analysis using online SPE

LC/MS/MS. Anal Chem 78: 1331. Altun Z., Abdel-Rehim M., and Blomberg L.G., 2004. New trends in sample preparation: Online microextraction in packed syringe (MEPS) for LC and GC applications Part III. J Chromatogr B 813: 129. Amini N. and Crescenzi C., 2003. Feasibility of an online restricted access materal/liquid chromatography/ tadem mass spectrometry method in the rapid and sensitive determination of organophosphorus trimesters in human blood plasma. J Chromatogr B 795: 245. Asperger A. et al., 2002. Trace determination of priority pesticide in water by means of high-speed online solid-phase extraction-liquid chromatography-tandem mass spectrometry using turbulent-flow chro-matography columns for enrichment and a short monolithic column for fast liquid chromatographic separation. J Chromatogr A 960: 109. Ayrton J. et al., 1997. The use of turbulent flow chromatography for the rapid, direct analysis of a novel pharmaceutical compound in plasma. Rapid Commun Mass Spectrom 11: 1953. Ayrton J. et al., 1998. Optimisation and routine use of generic ultra-high flow-rate liquid chromatography with mass spectrometric detection for the direct online analysis of pharmaceuticals in plasma. J Chromatogr A 8282: 199.

Ayrton J. et al., 1999. Ultra-high flow rate capillary liquid chromatography with mass spectrometric detection for the direct analysis of pharmaceuticals in plasma at sub-nanogram per millilitre concentrations. Rapid Commun Mass Spectrom 13: 1657. Barrett Y.C. et al., 2005. Automated online SPE LC-MS/MS method to quantitate 6-beta-hydroxycortisol and cortisol in human urine. J Chromatogr B 821: 159. Beaudry F. et al., 1998. In vivo pharmacokinetic screening in cassette dosing experiments: Use of online Prospekt liquid chromatography/atmospheric pressure chemical ionization tandem mass spectrometry technology in drug discovery. Rapid Commun Mass Spectrom 12: 1216. Blakley C.R., Carmody J.J., and Vestal M.L., 1980. A new soft ionization technique for mass spectrometry of complex molecules. J Am Chem Soc 102: 5931. Blakley C.R. and Vestal M.L., 1983. Themospray interface for liquid chromatography/mass spectrometry. Anal

Chem 55: 750. Boos K.S. et al., German Patent DE4130475A1. 1991.

Bourgogne E., Grivet C., and Hopfgartner G., 2005. Determination of talinolol in human plasma using automated online solid phase extraction combined with atmospheric pressure chemical ionization tandem mass spectrometry. J Chromatogr B 820: 103.

Brignol N. et al., 2000. Quantitatived analysis of terbinafine (Lamisil®) in human and minipig plasma by liquid chromatography tandem mass spectrometry. Rapid Commun Mass Spectrom 14: 141.

Calderoli S. et al., 2003. LC-MS-MS determination of brostallicin in human plasma following automated online SPE. J Pharm BiomedAnal 32: 601.

Ceglarek U. et al., 2004. Rapid simultaneous quantification of immunosuppressants in transplant patients by turbulent flow chromatography combined with tandem mass spectrometry. Clin Chim Acta 346: 181.

Chao M. et al., 2005. Rapid and sensitive quantification of urinary N7-mthelguanine by isotope-dilution liquid chromatography/electrospray ionization tandem mass spectrometry with online solid-phase extraction. Rapid Commun Mass Spectrom 19: 2427.

Chen Y., Wang C., and Wu K., 2005. Analysis of N7-(benzo[Oi]pyrene-6-yl)guanine in urine using two-step solid-phase extraction and isotope dilution with liquid chromatography/tandem mass spectrometry. Rapid Commun Mass Spectrom 19: 893.

Christiaens B. et al., 2004. Fully automated method for the liquid chromatographic-tandem mass spectrometric determination of cyproterone acetate in human plasma using restricted access material for online sample clean-up, J Chromatogr A 1056.

Clarke N. and Goldman M., Clinical applications of HTLC-MS/MS in the very high throughput diagnostic environment: LC-MS/MS on steroids. Application poster, Quest Diagnostics and Cohesive Technologies.

Dai S. et al., 2005. Quantitation of sifuvirtide in monkey plasma by an online solid-phase extraction procedure combined with liquid chromatography/electrospray ionization tandem mass spectrometry. Rapid Commun Mass Spectrom 19: 1273.

de Cassia R. et al., 2004. A rapid and sensitive method for simultaneous determination of lamivudine and zidovudine in human serum by online solid-phase extraction coupled to liquid chromatography/tandem mass spectrometry detection. Rapid Commun Mass Spectrom 18: 1147.

Ding J. and Neue U.D., 1999. A new approach to the effective preparation of plasma samples for rapid drug quantitation using online solid phase extraction mass spectrometry. Rapid Commun Mass Spectrom 13: 2151.

Doerge D.R., Churchwell M.I., and Delclos K.B., 2000. Online sample preparation using restricted-access media in the analysis of the soy isoflavones, genistein and daidzein, in rat serum using liquid chroma-tography electrospray mass spectrometry. Rapid Commun Mass Spectrom 14: 673.

Ferrer I. and Barceló, D., 1999. Simultaneous determination of antifouling herbicides in marina water samples by online solid-phase extraction followed by liquid chromatography-mass spectrometry. J Chromatogr A 854: 197.

Ferrer I. and Barceló, D., 2001. Identification of new degradation product of the antifouling agent irgarol 1051 in natural samples. J Chromatogr A 926: 221.

Gimeno R.A. et al., 2002. Determination of polycyclic aromatic hydrocarbons and polycyclic aromatic sulfur heterocycles by high-performance liquid chromatography with fluorescence and atmospheric pressure chemical ionization mass spectrometry detection in seawater and sediment samples. J Chromatogr A 958: 141.

Gon§alves J.C.S. et al., 2005. Online solid-phase extraction coupled with high-performance liquid chroma-tography and tandem mass spectrometry (SPE HPLC-MS-MS) for quantification of bromazepam in human plasma. Ther Drug Monit 27: 601.

Grant R.P., Cameron C., and Mackenzie-McMurter S., 2002. Generic serial and parallel online direct injection using turbulent flow liquid chromatography/tandem mass spectrometry. Rapid Commun Mass Spec-trom 16: 1785.

Gundersen T.E. and Blomhoff R., 1999. Online solid-phase extraction and isocratic separation of retinoic acid isomers in microbore column switching system. Meth Enzymol 299: 430.

Hennion M., 1999. Solid-phase extraction: Method development, sorbents, and coupling with liquid chromatography. J Chromatogr A 856: 3.

Herman J.L., 2002. Generic method for online extraction of drug substances in the presence of biological matrices using turbulent flow chromatography. Rapid Commun Mass Spectrom 16: 421.

Hernández F. et al., 1998. Coupled-column liquid chromatography applied to the trace-level determination of triazine herbicides and some of their metabolites in water. Anal Chem 70: 3322.

Hernández F. et al., 2001. Rapid direct determination of pesticides and metabolites in environmental water samples at sub-ug/L level by online solid-phase extraction-liquid chromatography-electrospray tandem mass spectrometry. J Chromatogr A 939: 1.

Hogenboom A.C., Niessen W.M.A., and Brinkman U.A., 1998. Rapid target analysis of microcontaminanant in water by online single-short-column liquid chromatography combined with atomospheric pressure chemical ionization ion-trap mass spectrometry. J Chromatogr A 794: 201.

Hogenboom A.C., Niessen W.M.A., and Brinkman U.A., 1999a. Online solid-phase extraction-short-column liquid chromatography combined with various tandem mass spectrometric scanning strategies for the rapid study of transformation of pesticides in surface water. J Chromatogr A 841: 33.

Hogenboom A.C. et al., 1999b. Accurate mass determination for the confirmation and identification of organic microcontaminants in surface water using online solid-phase extraction liquid chromatography elec-trospray orthogonal-acceleration time-of-flight mass spectrometry. Rapid Commun Mass Spectrom 13: 125.

Hopfgartner G., Husser C., and Zell M., 2002. High-throughput quantification of drugs and their metabolites in biosamples by LC-MS/MS: Possibilities and limitations. Ther Drug Monit 24: 134.

Hsieh Y. et al., 2000. Direct analysis of plasma samples for drug discovery compounds using mixed-function column liquid chromatography tandem mass spectrometry. Rapid Commun Mass Spectrom 14: 1384.

Hsieh Y. et al., 2001. Quantitative screening and matrix effect studies of drug discovery compounds in monkey plasma using fast-gradient liquid chromatography/tandem mass spectrometry. Rapid Commun Mass Spectrom 15: 2481.

Hsieh Y. et al., 2002. Direct simultaneous determination of drug discovery compounds in monkey plasma using mixed-function column liquid chromatography/tandem mass spectrometry. J Pharm Biomed Anal 27: 285.

Hsieh Y. et al., 2003. Direct plasma analysis of drug compounds using monolithic column liquid chromatography and tandem mass spectrometry. Anal Chem 75: 1812.

Hsieh Y., 2004. Using mass spectrometry for drug metabolism studies, in Direct Plasma Analysis Systems, Korfmacher, W.A., Ed., Boca Raton, FL, CRC Press, Chap. 5.

Hsieh S. et al., 2004. Increased throughput of parallel online extraction liquid chromatography/electrospray ionization tandem mass spectrometry system for GLP quantitative bioanalysis in drug development. Rapid Commun Mass Spectrom 18: 285.

Hu C. et al., 2006. Clinical-scale high-throughput analysis of urinary 8-oxo-7,8-dihydro-2'-deoxyquanosine by isotope-dilution liquid chromatography-tandem mass spectrometry with online solid-phase extraction. Clin Chem 52: 7.

Huang M.Q. et al., 2006. Increased productivity in quantitative bioanalysis using a monolith column coupled with high-flow direct-injection liquid chromatography/tandem mass spectrometry. Rapid Commun Mass Spectrom 20: 1709.

Ibanez M. et al., 2005. Residue determination of glyphosate, glufosinate and aminomethylphosphonic acid in water and soil samples by liquid chromatography coupled to electrospray tandem mass spectrometry. J Chromatogr A 1081: 145.

Jemal M., 2000. High-throughput quantitative bioanalysis by LC/MS/MS. Biomed Chromatogr 14: 422.

Jemal M., Xia Y., and Whigan D.B., 1998. The use of high-flow high performance liquid chromatography coupled with positive and negative ion electrospray tandem mass spectrometry for quantitative bioanalysis via direct injection of the plasma/serum samples. Rapid Commun Mass Spectrom 12: 1389.

Jemal M. et al., 1999. A versatile system of high-flow high performance liquid chromatography with tadem mass spectrometry for rapid direct-injection analysis of plasma samples for quantitation of a ¡-lactam drug candidate and its open-ring biotransformation product. Rapid Commun Mass Spectrom 13: 1462.

Jemal M., Ouyang Z., and Powell M.L., 2000. Direct-injection LC-MS-MS method for high-throughput simultaneous quantitation of simvastatin and simvastatin acid in human plasma. J Pharm Biomed Anal 23: 323.

Kahlich R. et al., 2006. Quantitative determination of piritramide in human plasma and urine by off- and online solid-phase extraction liquid chromatography coupled to tandem mass spectrometry. Rapid Commun Mass Spectrom 20: 275.

Kato K. et al., 2003. Determination of three phthalate metabolites in human urine using online solid-phase extraction-liquid chromatography-tandem mass spectrometry. J Chromatogr B 788: 407.

Kato K. et al., 2005. Determination of 16 phthalate metabolites in urine using automated sample preparation and online preconcentration/high-performance liquid chromatography/tandem mass spectrometry. Anal Chem 77: 2985.

Koal T. et al., 2004. Simultaneous determination of four immunosuppressant by means of high speed and robust online solid phase extraction-high performance liquid chromatography-tandem mass spectrometry. J Chromatogr B 805: 215.

Koeber R. et al., 2001. Evaluation of a multidimensional solid-phase extraction platform for highly selective online cleanup and high-throughput LC-MS analysis of triazines in river water samples using molecu-larly imprinted polymers. Anal Chem 73: 2437.

Kuhlenbeck D.L. et al., 2005. Online solid phase extraction using the Prospekt-2 coupled with a liquid chroma-tography/tandem mass spectrometer for the determination of dextromethorphan, detrophan and quai-fenesin in human plasma. Eur J Mass Spectrom 11: 199.

Kuklenyik Z., Needham L.L., and Calafat A.M., 2005. Measurement of 18 perfluorinated organic acids and amides in human serum using online solid-phase extraction. Anal Chem 77: 6085.

Lacorte S. and Barcelo D., 1995. Determination of organophosphorus pesticides and their transformation products in river waters by automated online solid-phase extraction followed by thermospray liquid chromatography. J Chromatogr A 712: 103.

Lant M.S. and Oxford J., 1987. Automated sample preparation online with thermospray high-performance liquid chromatography-mass spectrometry for the determination of drugs in plasma. J Chromatogr A 394: 223.

Löpez-Roldän P., de Alda M.J.L., and Barcelo D., 2004. Simultaneous determination of selected endocrine disrupters (pesticides, phenols and phthalates) in water by in-field solid-phase extraction (SPE) using the prototype PROFEXS followed by online SPE (PROSPEKT) and analysis by liquid chromatography-atomspheric pressure chemical ionization-mass spectrometry. Anal Bioanal Chem 378: 599.

Marchese A. et al., 1998. Determination of pranlukast and its metabolites in human plasma by LC/MS/MS with Prospekt™ online solid-phase extraction. J Mass Spectrom 33: 1071.

McLoughlin D.A., Olah T.V., and Gilbert J.D., 1997. A direct technique for the simultaneous determination of 10 drug candidates in plasma by liquid chromatography-atmospheric pressure chemical ionization mass spectrometry interfaced to a Prospekt solid-phase extraction system. J Pharm Biomed Anal 15: 1893.

Niederländer H.A.G. et al., 2006. High throughtput therapeutic drug monitoring of clozapine and metabolites in serum by online coupling of solid phase extraction with liquid chromatography-mass spectrometry. J Chromatogr B 834: 98.

Papadopouluo-Mourkidou E. et al., 2001. Use of an automated online SPE-HPLC method to monitor caffeine and selected aniline and phenol compounds in aquatic systems of Macedonia-Thrace, Greece. Fresenius J Anal Chem 371: 491.

Plumb R. et al., 2001. Direct analysis of pharmaceutical compounds in human plasma with chromatographic resolution using an alkyl-bonded silica rod column. Rapid Commun Mass Spectrom 15: 986.

Pozo O.J. et al., 2006. Efficient approach for the reliable quantification and confirmation of anitbiotice in water using online solid-phase extraction liquid chromatography/tandem mass spectrometry. J Chromatogr A 1103: 83.

Pretorius V. and Smuts T.W., 1966. Turbulent flow chromatography: A new approach to faster analysis. Anal Chem 38(2): 274.

Pruvost A. et al., 2000. Fully automated determination of eserine N-oxide in human plasma using online solidphase extraction with liquid chromatography coupled with electrospray ionization tandem mass spec-trometry. J Mass Spectrom 35: 625.

Quinn H.M. and Takarewski J.J., International Patent WO97/16724, 1997.

Raices R.S.L. et al., 2003. Determination of stavudine in human serum by online solid-phase extraction coupled to high-performance liquid chromatography with electrospray ionization tandem mass spectrometry: Application to a bioequivalence study. Rapid Commun Mass Spectrom 17: 1611.

Ramos L. et al., 2000. High-throughput approaches to the quantitative analysis of ketoconazole, a poten inhibitor of cytochrome P450 3A4, in huma plasma. Rapid Commun Mass Spectrom 14: 2282.

Riediker S. et al., 2002. Determination of chlormequat and mepiquat in pear, tomato, and wheat flour using online solid-phase extraction (Prospekt) coupled with liquid chromatography-electrospray ionization tandem mass spectrometry. J Chromatogr A 966: 15.

Rodriguez-Mozaz S., de Alda M.J.L., and Barcelo D., 2004. Picogram per liter level determination of estrogens in natural waters and waterworks by a fully automated online solid-phase extraction-liquid chromatog-raphy-electrospray tandem mass spectrometry method. Anal Chem 76: 6998.

Sancho J.V., Pozo O.J., and Hernández F., 2004. Liquid chromatography and tandem mass spectrometry: A powerful approach for the sensitive and rapid multiclass determination of pesticides and transformation products in water. Analyst 129: 38.

Schellen A. et al., 2000. High throughput online solid phase extraction/tandem mass spectrometric determination of paclitaxel in human serum. Rapid Commun Mass Spectrom 14: 230.

Schellen A. et al., 2003. Generic solid phase extraction-liquid chromatography-tandem mass spectrometry method for fast determination of drugs in biological fluids. J Chromatogr B 788: 251.

Souverian S. et al., 2003. Rapid analysis of fluoxetine and its metabolite in plasma by LC-MS with column-switching approach. Anal Bioanal Chem 377: 880.

Taylor R.L., Grebe S.K., and Singh R., High throughput analysis of 25-hydroxyvitamins D2 and D3 by LC-MS/ MS using automated online extraction. Application poster, Mayo Clinic and Cohesive Technologies.

van der Hoven R.A.M. et al., 1997. Liquid chromatography-mass spectrometry with online solid-phase extraction by a restricted-access C18 precolumn for direct plasma and urine injection. J Chromatogr A 762: 193.

Viehauer S. et al., 1995. Evaluation and routine application of the novel restricted-access precolumn packing material Alkyl-Diol Silica: Coupled-column high-performance liquid chromatographic analysis of the photoreactive drug 8-methoxypsoralen in plasma. J Chromatogr B 666: 315.

Vintiloiu A. et al., 2005. Combining restricted access material (RAM) and turbulent flow for the rapid online extraction of the cyclooxygenase-2 inhibitor rofecoxib in plasma samples. J Chromatogr A 1082: 150.

Visser N.F.C., Lingeman H., and Irth H., 2003. Online SPE-RP-LC for the determination of insulin derivatives in biological matrices. J Pharm Biomed Anal 32: 295.

Wachs T. and Henion J., 2003. A device for automated direct sampling and quantitation from solid-phase sor-bent extraction cards by electrospray tandem mass spectrometry. Anal Chem 75: 1769.

Wissiack R., Rosenberg E., and Grasserbauer M., 2000. Comparison of different sorbent materials for online solid-phase extraction with liquid chromatography-atmospheric pressure chemical ionization mass spectrometry of phenols. J Chromatogr B 896: 159.

Wu J. et al., 2000. Direct plasma sample injection in multiple-component LC-MS-MS assays for high-throughput pharmacokinetic screening. Anal Chem 72: 61.

Wu J. et al., 2001. Rapid Commun Mass Spectrom 15: 1113.

Xia Y. et al., 2000. Ternary-column system for high-throughput direct-injection bioanalysis by liquid chroma-tography/tadem mass spectrometry. Rapid Commun Mass Spectrom 14: 105.

Xu R.N. et al., 2006. A monolithic-phase based online extraction approach for determination of pharmaceutical compounds in human plasma by HPLC-MS/MS and a comparison with liquid-liquid extraction. J Pharm Biomed Anal 40: 728.

Xu X. et al., 2005. Quantitative determination of a novel dual PPAR a/g agonist using online turbulent flow extraction with liquid chromatography-tandem mass spectrometry. J Chromatogr B 814: 29.

Ye X. et al., 2005. Automated online column-switching HPLC-MS/MS method with peak focusing for the determnination of nine environmental phenols in urine. Anal Chem 77: 5407.

Ynddal L. and Hansen S.H., 2003. Online turbulent-flow chromatography-high-performance liquid chromatog-raphy-mass spectrometry for fast sample preparation and quantitation. J Chromatogr A 1020: 59.

Zang X. et al., 2005. A novel online solid-phase extraction approach integrated with a monolithic column and tandem mass spectrometry for direct plasma analysis of multiple drugs and metabolites. Rapid Commun Mass Spectrom 19: 3259.

Zell M., Erdin H.R., and Hopfgartner G., 1997a. Simultaneous dtermination of a potassium channel opener and its metabolite in rat plasma with column-switching liquid chromatography using atmospheric pressure chemical ionization. J Chromatogr B 694: 135.

Zell M., Husser C., and Hopfgartner G., 1997b. Column-switching high-performance liquid chromatography combined with ionspray tandem mass spectrometry for the simultaneous determination of the platelet inhibitor Ro 44-3888 and its pro-drug and precursor metabolite in plasma. J Mass Spectrom 32: 23.

Zeng H., Deng Y., and Wu J., 2003a. Fast analysis using monolithic columns coupled with high-flow online extraction and electrospray mass spectrometric detection for the direct and simultaneous quantitation of multiple components in plasma. J Chromatogr B 788: 331.

Zeng W. et al., 2003b. A direct injection high-throughput liquid chromatography tandem mass spectrometry method for the determination of orally active avb3 antagonist in huma urine and dialysate. Rapid Commun Mass Spectrom 17: 2475.

Zhang N. et al., 2000. Integrated sample collection and handling for drug discovery bioanalysis. J Pharm BiomedAnal 23: 551.

Zhou S. et al., 2005. High-throughput biological sample analysis using online turbulent flow extraction combined with monothic column liquid chromatography/tandem mass spectrometry. Rapid Commun Mass Spectrom 19: 2150.

Zimmer D. et al., 1999. Comparison of turbulent-flow chromatography with automated solid-phase extraction in 96-well plates and liquid-liquid extraction used as plasma sample preparation techniques for liquid chromatography-tandem mass spectrometry. J Chromatogr A 854: 1999.

Zwiener C. and Frimmel F., 2004. LC-MS analysis in the aquatic environment and in water treatment-a critical review. Par II: Applications for emerging contaminants and related pollutants, microorganisms and humic aicd. Anal Bioanal Chem 378: 862.

Was this article helpful?

+1 0

Post a comment